3
Enhanced Performance to Reduce Testing Time by 75%
TheMT9083BandMT9083Cseriesfeaturehighdynamicrange(upto45dB)allowingfibersover200kmtobemeasured.
Itisalsooptimizedatthemostcommonlyusedpulsewidthslike100nstoprovideexcellentresolutionandmeasurement
distancewhilegreatlyreducingtesttime.
New Feature Highlight
Optimized for Verifying Pon Splitters Up to 1 × 128 Count
ManyOTDRsclaimtobeabletotestsplitter-based,passiveopticalnetworks(PON)buttheMT9083delivers
inawayotherswishtheycould.Withitshighdynamicrangeandquickdataacquisition,theMT9083provides
unparalleledresolutionofsingleorcloselyspaced,cascadedsplittersuptoanindustry-leading1× 128count.
Feed cable from Central Office
Drop Cable
Pedestal with splitter
OLT
CO
Home
Up to 1 128 count
Fig. 2: Improved measurement range from MT9083A to MT9083B/C (100 ns shown)
MT9083B/C
(Enhanced Mode)
MT9083A
10 sec.
100 sec.
Wavelength: 1550 nm
Distance range: 50 km
Pulse width: 100 ns
20 40 60 80 100 120 (sec)
Fig 1: Typical PON 1 × 64 count System Measurement from the customer premise.
TheMT9083BorCEnhancedRangeModeandaPulsewidthof100nsprovidesexcellentdynamicrange
whilenotcompromisingdeadzoneresolutiontoclearlydisplaymultiple,highlosssplitters.
200 m
MT9083A Noise Floor
Measurementtime:10sec
MT9083B/C Noise Floor